HyreElectrical

Quick answer

Aluminum wiring is house wiring that uses aluminum conductors instead of copper, and in US homes the term usually means the small aluminum branch circuits for outlets and lights installed from about 1965 to the mid-1970s.

The concern is the connections. CPSC found that pre-1972 homes wired with aluminum were 55 times more likely to have outlet connections reach fire hazard conditions than copper-wired homes.

Quick facts

The key facts about Aluminum Wiring, with sources:

Installed mainly
1965 to the mid-1970s, during a copper shortage 2
Main hazard
Overheating at connections and splices 2
Survey finding
Pre-1972 aluminum homes 55 times more likely to have outlet connections reach fire hazard conditions 2
How to spot it
"AL" or "Aluminum" printed on the cable jacket 2
Sizes used
12 AWG for 15 A and 10 AWG for 20 A circuits 2
CPSC-recognized permanent repairs
Rewire with copper; COPALUM crimp pigtails; AlumiConn connector if COPALUM is unavailable 2

Key takeaways

  • Aluminum wiring is not the same as aluminum service cable; the concern is small branch circuits.
  • Homes wired between 1965 and the mid-1970s may have it 2.
  • The wire itself is not the main problem; connections can overheat with no warning signs.
  • CPSC lists three permanent fixes: rewiring with copper, COPALUM pigtails and, where COPALUM is unavailable, AlumiConn connectors 2.
  • Every repair is a job for a qualified electrician.

If you think you have aluminum wiring

Safety and risk

Do not open outlets, switches or the panel to check. CPSC warns that doing it yourself can get you electrocuted or make the problem worse 2.

Hot-to-the-touch cover plates, flickering lights, dead circuits or a smell of burning plastic are reasons to stop using that circuit and call a licensed electrician. If you see smoke or flame, leave and call 911.

What aluminum wiring is

In the mid-1960s a copper shortage led builders to move aluminum wire from large circuits, such as dryers and ranges, into everyday 15- and 20-amp outlet and light circuits 2. That is what people mean by "aluminum wiring" in a house.

CPSC says homes built before 1965 are unlikely to have aluminum branch wiring, while cable installed from 1965 to the mid-1970s in new homes, additions and rewired circuits may contain it 2. It looks like ordinary plastic-sheathed NM cable from the outside.

Large aluminum conductors are still common and accepted today for service entrance cables and feeders. CPSC's repair advice does not apply to those larger conductors, or to dryer and range circuits 2. This page is about the small branch circuits.

How aluminum connections fail

CPSC describes several aging processes at aluminum connections that raise resistance over time. The damage builds on itself. More resistance means more heat whenever current flows, sometimes to dangerous levels 2.

The failures happen where wires end or join: outlets, switches, junction boxes and the connections at appliances such as dishwashers and furnaces 2. The wire inside the wall usually is not where the fire starts.

In the CPSC-funded survey, "fire hazard conditions" meant an outlet cover screw reached 149°C (300°F), sparks came from the outlet, or nearby material was charred 2.

Cycle How an aluminum connection heats up
  1. Connection agesdeterioration at the screw or splice
  2. Resistance risesmore opposition to current
  3. Heat buildswhen the circuit carries load
  4. Damage adds upthe joint gets worse each cycle
  5. Back to step 1

Source: [2]

Kinds of aluminum conductors in a home

TypeWhere foundStatus
Solid aluminum branch wiring (12 and 10 AWG)Outlets, switches, lights in 1965 to mid-1970s homesThe fire concern CPSC addresses 2
Copper-clad aluminumSome branch wiring of the eraNot covered by CPSC repair advice; marked "CU-clad" 2
Stranded aluminum service and feeder cableService entrance, subpanel feedersCommon today; outside CPSC's branch repair advice 2
Aluminum range and dryer circuitsLarge 240-volt appliancesOutside CPSC's branch repair advice 2

Example: why aluminum circuits use a larger size

Aluminum carries less current than copper of the same size, so aluminum branch circuits were sized one step larger. This example compares manufacturer chart values in the 75°C column.

SizeCopper ampacity (75°C)Aluminum ampacity (75°C)
12 AWG25 A 320 A 3
10 AWG35 A 330 A 3
Branch circuit practice14 AWG for 15 A, 12 AWG for 20 A12 AWG for 15 A, 10 AWG for 20 A 2
Chart Copper vs aluminum ampacity, 75°C column

At the same size, aluminum carries about 5 amps less than copper in these rows: 20 versus 25 amps at 12 AWG and 30 versus 35 at 10 AWG.

Copper vs aluminum ampacity, 75°C column (amps)
ItemValue (amps)
12 AWG copper 25 A
12 AWG aluminum 20 A
10 AWG copper 35 A
10 AWG aluminum 30 A

Data period: Cerrowire ampacity chart, 2017 NEC basis; retrieved 2026-10-10

Source: [3]

So a 15-amp aluminum circuit has thicker wire than a copper one. That is one clue an electrician uses. The printed "AL" on the jacket is the surer sign.

Where to look, safely

CPSC says nearly all aluminum branch wiring was installed as plastic-sheathed NM cable. Look at the printed or embossed markings on cable jackets in unfinished basements, attics or garages. A flashlight held at a low angle helps read embossed text. Aluminum cable is marked "AL" or "Aluminum" every few feet 2.

Read the whole marking. "CU-clad" or "Copper-clad" with "AL" means copper-coated aluminum, which CPSC's repair advice does not cover 2. If you cannot see any cable, ask an electrician or home inspector. Do not remove cover plates.

Why it was used, and what still works

There is no safety benefit to aluminum branch wiring in a home today. The honest angle is why it was chosen and where aluminum is still fine.

  • It was cheaper and available during the 1960s copper shortage 2.
  • Large aluminum conductors remain standard for service and feeder cable.
  • An existing aluminum system can be made safer without full rewiring, using a CPSC-recognized connection repair 2.

Why it is a problem

  • Connections can fail and overheat with no prior warning signs 2.
  • Ordinary outlets and switches not rated for aluminum are a poor match.
  • Twist-on connectors used as "pigtail" repairs overheated in CPSC testing 2.
  • Some insurers charge more or decline homes with it, which can affect coverage or a sale 1.
  • Every connection in the house must be addressed to get the full benefit of a repair 2.

What drives the cost of fixing it

Cost depends on the repair method and the number of connections. Rewiring with copper removes the hazard but may be impractical or costly in finished homes 2. Pigtail repairs scale with the count of outlets, switches, fixtures, boxes and appliance connections, since CPSC says each one should be done.

COPALUM is installed only by electricians trained by the maker using a special tool, which affects availability 2. We do not quote prices without dated, sourced figures. See aluminum wiring remediation for how the work is scoped, and the project cost tool for drivers.

The repair options CPSC recognizes

CPSC names three permanent repairs and warns against two common shortcuts. All require a qualified electrician 2.

MethodWhat it isCPSC view
Rewire with copperNew copper branch circuits; old aluminum abandonedThe best method, but may be impractical or expensive
COPALUM crimp pigtailShort copper lead joined to aluminum by a tool-applied crimpSafe and permanent; trained installers only
AlumiConn pigtailSet-screw connector joining copper to aluminumNext best if COPALUM is unavailable; shorter track record
Twist-on connector pigtailsStandard wire nutsNot recommended; overheated in testing
CO/ALR devices onlyOutlets and switches rated for aluminumNot a full permanent repair in CPSC's view
Side by side Repair paths at a glance

Rewire

  • Removes aluminum
  • Most disruptive

COPALUM

  • Keeps wire, fixes every joint
  • Trained installers only

AlumiConn

  • Keeps wire, fixes every joint
  • Use if COPALUM is unavailable

Source: [2]

Sources: [2]

Living with aluminum wiring until it is fixed

There is no owner maintenance that makes aluminum connections safe. What you can do: avoid heavy loads such as space heaters on aluminum circuits, keep working smoke alarms, and notice warm plates or odd smells.

After a repair, keep the records. They help with insurance and resale. An electrician should check any later additions use rated connectors.

Warning signs CPSC lists

CPSC notes failing aluminum connections often give no easy warning 2. When signs do appear, they include:

  • Cover plates on outlets or switches that are hot to the touch.
  • Flickering lights.
  • Circuits that stop working.
  • The smell of burning plastic at outlets or switches.

Any of these calls for a licensed electrician. Our electrical safety check lists other red flags, and emergency electricians handle urgent cases.

Authorities and rules

The main federal guidance is CPSC Publication 516, Repairing Aluminum Wiring, dated June 2011 2. It is advice, not a law requiring homeowners to replace existing wiring. It distinguishes existing aluminum circuits from the larger aluminum conductors used today.

For new work, NFPA 70, the National Electrical Code, governs conductor sizes and terminations; Table 310.16 in the 2023 edition lists aluminum ampacity separately from copper 4 5.

Local codes adopt editions on their own schedule 6. CPSC's publication does not order existing wiring removed. When circuits are altered, repaired or extended, the local code official decides which edition the new work must meet.

Aluminum wiring compared with related terms

TermWhat it isConnection to aluminum wiring
Wire gaugeConductor sizeAluminum runs one size larger than copper
Wire connectorDevice that joins wiresMust be rated for aluminum; key to repair
NM cablePlastic-sheathed cableHow aluminum branch wire was installed
Knob-and-tubeOlder open copper wiringDifferent era and hazard; see knob-and-tube guide
Arc faultUnintended arcingLoose, hot connections can arc

Myths about aluminum wiring

Myth All aluminum wire is dangerous.
Reality CPSC's concern is small branch circuits; large aluminum service and feeder cable is common today 2.
Myth If nothing has happened yet, it is fine.
Reality CPSC notes connections can fail with no prior warning 2.
Myth Wire nuts fix it.
Reality Twist-on pigtails overheated in CPSC testing and are not a recommended repair 2.
Myth Swapping in CO/ALR outlets solves it.
Reality CPSC does not consider that a full permanent repair 2.
Myth Copper-clad is the same as aluminum.
Reality CPSC's repair advice does not cover copper-clad aluminum 2.

Where it varies

Aluminum branch wiring is tied to construction era, not climate, so homes built or expanded from 1965 to the mid-1970s are the ones to check anywhere 2. What changes by state is the NEC edition used for repair work and who is licensed to do it 6.

When aluminum wiring matters to you

Aluminum wiring matters if you own or are buying a home built or rewired from about 1965 to the mid-1970s, or an inspection report mentions "single-strand aluminum". It also matters before adding loads or renovating, since new work must connect properly to old wire.

Next step: read our full aluminum wiring guide, then have a licensed electrician confirm what you have and quote a CPSC-recognized repair.

Decision guide What to do next
If Home built 1965 to mid-1970s
Then Look for "AL" on visible cable jackets
If Jacket says AL, not CU-clad
Then Get an electrician to assess
If Warm plates or burning smell
Then Stop using the circuit; call now
If Choosing a repair
Then Rewire, COPALUM or AlumiConn per CPSC

Source: [2]

Questions about Aluminum Wiring

Is aluminum wiring dangerous?

Aluminum branch wiring carries a higher fire risk than copper at its connections. A CPSC-funded survey found pre-1972 homes wired with aluminum were 55 times more likely to have outlet connections reach fire hazard conditions.

The risk sits at outlets, switches and splices. A CPSC-recognized repair reduces it. CPSC also warns that these connections can fail and overheat without any prior warning signs, so a quiet history is not proof of safety 2.

How do I know if my house has aluminum wiring?

Look at the printed markings on cable jackets in an unfinished basement, attic or garage. Aluminum cable is marked "AL" or "Aluminum" every few feet. A home built or rewired from 1965 to the mid-1970s is the likeliest. If you cannot see cable, have an electrician check. Do not remove covers.

What years was aluminum wiring used in homes?

CPSC says aluminum branch circuit wiring went into homes from about 1965 to the mid-1970s, during a copper shortage. Homes built before 1965 are unlikely to have it.

Additions and rewired circuits from that period may contain it even in older houses.

A 1950s house with a 1970 family-room addition, for example, can have aluminum in the addition only, so check cable in each part of the home.

Do I have to replace aluminum wiring?

Not necessarily. CPSC recognizes full copper rewiring as the best fix, but also two connection repairs that keep the existing wire: COPALUM crimp pigtails, or AlumiConn connectors where COPALUM is unavailable.

Each must be done at every aluminum connection by a qualified electrician. CPSC lists outlets, switches, light fixtures, junction boxes and hard-wired appliances among the places that need it 2.

What is pigtailing aluminum wiring?

Pigtailing joins a short copper wire to the end of the aluminum wire, so outlets and switches connect to copper. CPSC recommends it only with a COPALUM crimp or, as a fallback, an AlumiConn connector.

Pigtails made with ordinary twist-on connectors overheated in CPSC testing. A COPALUM crimp needs a special tool and a maker-trained installer, so ask any electrician who quotes it whether they hold that training 2.

Are CO/ALR outlets enough for aluminum wiring?

CPSC does not treat CO/ALR outlets and switches as a complete permanent repair.

They are rated for aluminum and work better than standard devices when installed carefully, but they do not address splices, boxes and appliance connections. CPSC prefers rewiring, COPALUM or AlumiConn.

CPSC accepts CO/ALR devices only as an emergency, temporary repair for a failed aluminum termination 2.

Does aluminum wiring affect home insurance?

Aluminum wiring can affect home insurance. Policygenius reports that many standard insurers charge more for or decline homes with aluminum branch wiring, and that an insurer may require repairs after an inspection. Policies differ by company and state.

Records of a CPSC-recognized repair by a licensed electrician give you something to show when you shop for coverage or sell. Ask your agent which repair methods the company accepts before the work starts, since rules differ.

Is aluminum wire still used today?

Yes, in larger sizes. Aluminum is common for service entrance cables and feeders to subpanels. CPSC's concerns and repair advice apply to small 15- and 20-amp branch circuits, not to these larger conductors 2.

CPSC also excludes dryer and range circuits from its branch repair advice. Large aluminum feeders need lugs rated for aluminum, which an electrician checks at every termination.

What is copper-clad aluminum wire?

Copper-clad aluminum has an aluminum core with a copper coating. Its jacket is marked "CU-clad" or "Copper-clad" with "AL".

CPSC notes its aluminum repair recommendations do not cover copper-clad wire, so an electrician should assess it separately.

CPSC notes that copper-clad and solid aluminum cable were sized the same way: 12 AWG for 15-amp and 10 AWG for 20-amp circuits 2.

Can I add new circuits to a house with aluminum wiring?

Yes. New circuits can be run in copper from the panel. Any place where new work connects to existing aluminum needs connectors rated for it.

Ask the electrician to inspect the existing aluminum connections at the same time. Opening walls for new work is a convenient moment to pigtail nearby aluminum outlets and switches as well.

Sources

  1. Policygenius, Does homeowners insurance cover aluminum wiring?, retrieved .
  2. U.S. Consumer Product Safety Commission, Publication 516: Repairing Aluminum Wiring (June 2011), retrieved .
  3. Cerrowire, Ampacity Charts (copper and aluminum, 2017 NEC basis), retrieved .
  4. NFPA, NFPA 70 (National Electrical Code) code development page, retrieved .
  5. NFPA, Free access to NFPA codes and standards, retrieved .
  6. NFPA, Where the NEC is enforced (adoption maps), retrieved .