Whole-house rewiring: when the wiring itself is the problem

Knob-and-tube, early cloth-insulated cable, and aluminum branch circuits are three eras, three remediations, and three insurance conversations. Treating them as one job is how people buy the wrong work.

Updated September 2026 · Data as of 5 September 2026

Written by HyreElectrical Research Desk Primary-source research and fact checking

3 eras three jobs, not one rewire Knob-and-tube, cloth, aluminum branch — different remediation, different insurer question
11.5% of US housing was built 1939 or earlier ACS 2024 1-year, table B25034. Original construction, not remaining knob-and-tube.
K&T listed unacceptable at Citizens, with no repair footnote Home Condition Requirements, 1 March 2023
We do not pull cable or pull the permit HyreElectrical does not perform electrical work

The short answer

You rewire a house when the wiring method in the walls is the problem — not because the cover on the panel is ugly, and not because a neighbor just did a 200-amp service. The method is one of three eras, and they are not interchangeable. Knob-and-tube is an ungrounded open-air system that the model code still describes, but only for extensions of existing installations, and that a named Florida residual-market carrier lists as an unacceptable condition with no repair-in-place path on its published sheet. Early cloth-insulated cable is a later, jacketed method whose rubber insulation ages and which was commonly installed without an equipment grounding conductor until the 1962 National Electrical Code. Aluminum branch wiring is a 1960s–mid-1970s product whose hazard is at the connections; the Consumer Product Safety Commission names three permanent methods, and only one of them is a copper rewire. Year the house was built is a reason to look, not a diagnosis: Census ACS records year of original construction, not the metal or the jacket in the walls today. HyreElectrical does not perform electrical work. Matching is still being built, and our verified contractor records cover five states, 74% of them Florida.

Stop. This is licensed work.

Burning plastic, sparking, a receptacle or switch cover that is hot to the touch, or a breaker or fuse that will not hold is a stop, not a project. Use the electrical safety check as a stop list, then call a licensed electrician. Do not open the panel. Do not open outlet or switch boxes. Do not “just snip the old knob-and-tube” in the attic. Do not wrap damaged cloth insulation with tape and call it a repair.

CPSC’s consumer advice on aluminum wiring is the right stop line for every era on this page: you could be electrocuted, or you could make the problem worse. Homeowner actions here are: look at unfinished space without touching conductors, ask which era and which method, ask the insurer what it will accept in writing, and hire a licensed electrician who already pulls permits in this jurisdiction. HyreElectrical does not perform electrical work, inspect houses, or dispatch anyone.

Three eras, three jobs

EraWhat it isThe usual jobThe insurance question
Knob-and-tubeIndividual hot and neutral conductors on porcelain knobs and tubes. No equipment grounding conductor. Designed to run in free air.Replace the live circuits with a modern grounded wiring method. Abandon-in-place is common once the circuit is dead. Covering live K&T with thermal insulation is a model-code “uses not permitted.”Ask whether the carrier will bind a policy on a house that still has active knob-and-tube. Citizens Property Insurance lists knob-and-tube as an unacceptable condition, with no repair-in-place footnote of the kind it publishes for aluminum.
Early grounded cloth (and ungrounded cloth NM)Jacketed cable: cloth-braid NM, or armored cable (BX / Type AC), with rubber-insulated conductors. Grounding arrives late — 1962 for all branch circuits in the model code.Replace damaged or ungrounded runs; or rewire rooms as they are opened. A GFCI receptacle labeled “No Equipment Ground” is a shock-protection substitute, not a rewire and not an equipment ground.Ask what the 4-point or equivalent inspection has to say about the condition of the insulation and whether circuits are grounded. Citizens’ 1 March 2023 sheet does not name cloth as a separate uninsurable category; condition and hazardous findings still matter.
Aluminum branchSolid aluminum on 15- and 20-ampere general-purpose circuits, typically 1965 through the mid-1970s. The hazard CPSC investigated is at the connections, not in the run of cable.One of three CPSC permanent methods: copper rewire, COPALUM crimp, or AlumiConn if COPALUM is unavailable. The last two leave the aluminum in the walls. Detail lives on the aluminum remediation page.Ask, in writing, which of the three methods the carrier will accept. Citizens will accept documented COPALUM, documented AlumiConn, or a full copper rewire. That is one named carrier, not a national rule.

Three wiring methods, three remediations, three underwriting conversations. A quote that says only “rewire the house” has not chosen among them.

A licensed electrician looking at the installation names the method. Year built is a prompt to look, not a substitute for looking. This table is a map of the conversation, not a diagnosis of your house.

Year built is a proxy for original construction — not a census of what is in the walls

The American Community Survey does not record conductor metal, jacket material, or whether a house has been rewired. Table B25034 records year the structure was built. That is a useful prompt: original construction in the United States used different wiring methods in different decades. It is not a count of remaining knob-and-tube, remaining cloth NM, or remaining aluminum branch circuits.

HyreElectrical calculation from the ACS 2024 1-year estimates, table B25034 (universe: housing units, United States), retrieved 5 September 2026: 146,740,960 housing units. Of those, 16,821,220 (11.5%) were built in 1939 or earlier; 6,210,969 (4.2%) in 1940–1949; 13,358,031 (9.1%) in 1950–1959; 14,113,943 (9.6%) in 1960–1969; and 20,140,924 (13.7%) in 1970–1979.

Those bands are the original-construction windows most often associated with the three eras on this page. Knob-and-tube was the dominant residential method into the 1930s and was still being installed, in some places, into the 1940s. Cloth-braid NM was listed in the NEC in 1926 and was ordinary construction through the 1950s and into the early 1960s. Solid aluminum branch wiring belongs to a much shorter window — CPSC’s pamphlet names 1965 through the mid-1970s.

None of those sentences is a remaining-stock count. Combined, units built in 1939 or earlier plus 1940–1959 total 36,390,220, or 24.8% of the ACS 2024 1-year stock — a pre-1960 original-construction proxy for ungrounded or early-grounded methods. Combined 1960–1979 units total 34,254,867, or 23.3% — a year-built proxy that includes millions of copper-wired houses and excludes any 1965–1973 aluminum that has already been remediated. Anyone selling “X million American homes still have knob-and-tube” or “still have aluminum” from ACS year-built is inflating a proxy into a census. We will not.

A 1912 house that was gutted in 1998 has modern NM in the walls and an ACS year-built of 1912. A 1971 house that has never been opened may still have original aluminum. The cable marking, the porcelain knobs, and a licensed electrician are the evidence. The year is the reason to look.

Built 1939 or earlier (K&T-era original construction proxy)16.8 million
Not a count of remaining knob-and-tube
Built 1940–1959 (cloth / early-grounded original construction proxy)19.6 million
Not a count of remaining cloth NM
Built 1960–1979 (aluminum-era original construction proxy)34.3 million
Includes millions of copper-wired houses

Year-built stock is the wrong denominator for remaining old wiring. Each bar is housing units still standing from those years, as of the ACS 2024 1-year estimates. Original construction method is a probability, not a finding.

How residential wiring methods actually changed

The dates below are from primary or near-primary records of the method and of the model code — not from contractor blogs that collapse a century into “old wiring.” David A. Dini, P.E., of Underwriters Laboratories, published the wiring-method chronology in 2006; the grounding-receptacle dates are the NEC’s, as Dini records them.

  1. 1890s–1930s

    Knob-and-tube is the residential method

    Individual conductors, porcelain knobs and tubes, cotton-braid “loom” at terminations. Dini: the system began being phased out in the 1930s as NM and armored cable gained share. It is still described in the model code, now Article 394, for existing installations and by special permission.

  2. 1899 / 1903

    Armored cable (BX) is listed, then coded

    Sprague Electric’s flexible steel-armored conductors, experimental versions “AX” and “BX.” BX became the production article and later a GE trade name. Armored cable first appeared in the 1903 NEC; Dini says it did not become popular until around 1930. Type AC is Article 320. A bonding strip under the armor was required after 1959.

  3. 1926

    Nonmetallic-sheathed cable enters the NEC

    NM was invented a few years earlier at General Cable’s Rome Wire Division in Rome, New York, and marketed as Romex. Early NM had cotton-braid jackets over rubber-insulated conductors and, for residential use, typically no equipment grounding conductor.

  4. 1947 / 1956 / 1962

    Grounding arrives at the receptacle, then at every branch circuit

    1947 NEC: grounding-type receptacles required for the laundry. 1956: extended to basements, garages, outdoors, and other areas where a person might be standing on ground. 1962: all branch circuits must include a grounding conductor or ground path to which the receptacle’s grounding contacts are connected. That is the line between “early cloth” and modern grounded NM. Why that conductor matters, and why grounding and bonding are two different jobs, is the grounding and bonding guide.

  5. Early 1960s – 1984

    Thermoplastic replaces the braid

    Dini: thermoplastic began replacing the braided jacket in the early 1960s; by about 1970 most NM had a PVC outer jacket, though a braid was still permitted until 1984. NM-B (90°C conductors, 75°C jacket) arrived in 1984. Rubber-insulated cloth and plastic-jacketed NM can coexist in one house.

  6. 1965 – mid-1970s

    Solid aluminum on 15- and 20-ampere circuits

    CPSC: a copper shortage moved aluminum from a few large-power circuits onto general-purpose branch circuits. The 2003 news release estimated two million homes built with aluminum wire between 1965 and 1973. That is an era estimate of original installations, not remaining stock. The child page owns the methods.

  7. 1987 (then Art. 324-4)

    The model code forbids insulating over knob-and-tube

    DOE’s Weatherization Assistance Program, restating the NEC change: concealed knob-and-tube shall not be used in hollow spaces of walls, ceilings and attics when those spaces are insulated by loose or rolled insulating material — later editions add foamed-in-place. Some states amend that rule. The model code is not your city.

Dini’s 2006 UL paper is a history of practice and of NEC provisions as of that date. Confirm the edition your jurisdiction has adopted before treating any of these dates as a local requirement.

Knob-and-tube: an ungrounded system that was designed to run in free air

Knob-and-tube is not “old Romex.” It is a different wiring method. Individual insulated conductors — a hot and a neutral, no equipment grounding conductor — are supported on porcelain knobs along framing, and they pass through framing in porcelain tubes. Splices in original work were made in free air, soldered and taped, not landed in a junction box. Where a conductor entered a box or a fixture, a woven cotton tube called loom covered the end. David A. Dini of Underwriters Laboratories, writing in 2006, records that the conductors were run spaced at least 2½ inches apart where exposed, and that knobs were not to support two wires of opposite polarity on the same insulator.

The physics of the method is the part later renovations break. Open wiring dissipates heat into free air. That is not a nostalgic flourish; it is why the model code still cares about insulation. NFPA 70, Article 394, still defines concealed knob-and-tube wiring and still permits it only for extensions of existing installations, or elsewhere by special permission from the authority having jurisdiction. Article 394.12 lists uses not permitted. Among them, in current editions: hollow spaces of walls, ceilings, and attics where those spaces are insulated by loose, rolled, or foamed-in-place insulating material that envelops the conductors. The 2017 NEC Handbook’s commentary on that prohibition is blunt: blown-in, foamed-in, or rolled insulation prevents dissipation of heat into the free-air space, resulting in higher conductor temperature, which could cause insulation breakdown and possible insulation ignition.

That is a model-code statement about new or extended concealed knob-and-tube in insulated cavities. Existing K&T that someone later buried in cellulose is a different, worse sentence: the original heat path is gone, and the rubber or cloth insulation on the conductors is a century old. CPSC staff put a number on the insulation-and-wiring combination in 1980. Release 80-002, 6 February 1980: staff estimated that more than 2,000 household fires occur every year when thermal insulation is ignited by faulty wiring or lighting fixtures, about three percent of the then-estimated 75,000 electrical-system fires annually. Staff’s mechanism, in the same release: the fire potential from damaged wiring or over-fused circuitry is greatly increased when the heat given off by the wiring — which normally is dissipated through free air circulation — is confined by thermal insulation. That 1980 estimate is not a 2026 remaining-K&T fire count. It is the federal safety agency stating the mechanism this page is using.

Dini records the same 1970s energy-crisis pattern from the laboratory side: loose-fill cellulose blown into attics and walls of older houses became a problem where knob-and-tube splices had glowing connections or overheated conductors. Glow is not a metaphor. Open splices can run hot for a long time without a box, without a cover, and without a ground-fault path.

The other structural fact is the missing equipment grounding conductor. There is no third wire. There is no armor to use as a ground path, as there is with Type AC. Three-prong appliances on a knob-and-tube circuit do not have an equipment ground, no matter what the receptacle looks like. Cheater plugs and three-prong replacements that are not GFCI-protected, not labeled, and not actually grounded are how that fact gets laundered into a listing photograph.

What the model code does not say is that existing knob-and-tube must be ripped out on sight. Article 394 exists because the method is still in buildings. New work in the method is limited to extensions of existing installations or special permission. Complete removal is an insurance, a renovation, a load, or a condition decision — not a sentence the NEC prints as a national mandate. InterNACHI and a great deal of contractor copy collapse that distinction. This page will not.

What actually makes knob-and-tube a job

Unmodified original K&T in free air is not the same finding as modified, overfused, or insulated K&T. The insurer may not care about that distinction. The electrician should.

Condition and modification findings

Thermal insulation enveloping live conductors. That is the Article 394.12 fact pattern, and it is the CPSC 1980 mechanism. An energy retrofit that blew cellulose over live K&T did not “weatherize around the wiring.” It changed the thermal environment the method was designed for.

Splices into modern cable, often without a box. A Romex tail twisted onto a knob-and-tube run in an attic, taped, and stuffed into insulation is not an extension the model code contemplates. It is the most common field modification inspectors describe.

Overfusing. Original K&T is typically 14 AWG on lighting and receptacle circuits. A 20- or 30-amp fuse on that conductor is how the overcurrent device stops being a device. The Fire Protection Research Foundation’s 2008 Residential Electrical System Aging study found houses still using plug fuses where 30-amp fuses were protecting 14 or 12 AWG copper — a finding about overcurrent abuse, not about porcelain knobs as such.

Damaged insulation, rodent chewing, foot traffic in attics. Rubber and fiber insulation that has dried and cracked leaves bare conductor. That is a condition finding. It is diagnosed in unfinished space, not from the year on the tax record.

What is not, by itself, the finding

The mere presence of porcelain in an unfinished attic. Abandoned K&T is often left in place when a house is rewired. Dead porcelain is not live K&T. A licensed electrician determines which is which. Do not assume, and do not tug.

“The code requires it all to come out.” The model code restricts new and extended concealed K&T. It does not print a national removal order for existing installations. Your city may be stricter. Ask the building department, not a blog.

Two-prong receptacles as proof of K&T. Ungrounded cloth NM produces the same receptacle. So does a later grounded cable that someone capped. The unfinished attic or basement is where the method is identified.

A new panel as a K&T repair. Swapping the load center does not put an equipment grounding conductor in the walls and does not take the conductors out of the insulation. See panel upgrade for the bus. This page is the walls.

The knob-and-tube insurance conversation is not the aluminum conversation

There is no national underwriting rule we can cite. Carrier manuals are not a federal dataset. The honest move is the same one the aluminum child page makes: quote a named carrier, date the retrieval, and tell you to get your own carrier’s answer in writing.

Citizens Property Insurance Corporation is Florida’s residual-market carrier. Its public “Home Condition Requirements” sheet for new-business HO-3, HO-8, DP-1 and DP-3 (dated 1 March 2023, retrieved 5 September 2026) lists knob and tube wiring under Unacceptable Conditions, alongside “fewer than 100 amps,” “aluminum branch circuit wiring,” and a list of hazardous conditions (inadequate fusing, open circuits or missing knockouts, frayed or loose wiring, double taps). Acceptable conditions on the same sheet include 100 amps or more, circuit breakers/220 volts, fuses, and multi-strand aluminum wiring.

Read the asterisk. Aluminum branch circuit wiring carries a footnote: upload documentation that the property was remediated using a method acceptable to Citizens, and see Uninsurable Properties in the underwriting manual. Knob and tube wiring does not carry that footnote on this sheet. Aluminum has a published remediation path at Citizens — COPALUM, AlumiConn, or a full copper rewire, as the carrier’s separate FAQ (Answer ID 1550, updated 16 April 2026) spells out. Knob-and-tube, on the condition sheet, is listed as unacceptable, full stop.

HyreElectrical analysis: that is the information-gain of scoping by era. A household that treats “old wiring” as one underwriting problem will hear “CPSC-approved connectors” in an aluminum conversation and assume the same paper works for knob-and-tube. It does not, at this named carrier, on this dated sheet. COPALUM is an aluminum-to-copper connection repair. It has nothing to do with porcelain knobs. Asking for a “rewire or connectors, whichever is cheaper” on a K&T house is asking the wrong menu.

Citizens is one Florida residual-market carrier. Florida is relevant on this site because 74% of our contractor records are there, which we have already disclosed, and because Citizens publishes the rule. It is not a national fact that “insurers refuse knob-and-tube.” Some admitted carriers in other states will write a house with documented, inspected, uninsulated K&T; some will not write it at any price. Get the answer from the carrier that will actually bind the policy, named method, in writing, before you pay for one.

A 4-point inspection in Florida is how this conversation usually starts. Citizens requires a completed 4-point form for homes over 20 years old, verifying that the electrical system is in an acceptable condition and has sufficient amperage, and says: if an inspector indicates the electrical system is not in good working order, do not submit without proof of repairs or updates. Active knob-and-tube is not an “acceptable condition” on the sheet above. That is why a sale, a refinance, or a change of carrier is a common trigger for a K&T rewire even when the lights still work.

Cloth-insulated cable is the generation after knob-and-tube — and it is not one product

People say “cloth wiring” as if it were a single SKU. It is at least two methods, and the grounding question splits each of them in half. Getting this wrong is how a house is either over-rewired or left ungrounded with a fresh coat of three-prong receptacles.

Cloth-braid NM is early nonmetallic-sheathed cable: two (later three) rubber-insulated conductors inside a woven cotton or rayon jacket, often tarred or varnished. Dini: NM was first listed and described in the NEC in 1926; General Cable’s Rome Wire Division had invented it a few years earlier as Romex. Until the early 1960s, most NM for residential use did not have a grounding conductor. Around 1950, synthetic spun rayon was permitted to replace cotton in the braid. In the early 1960s thermoplastic began replacing the braid; by about 1970 most NM had a PVC jacket, though a braid was still permitted until 1984. That means a house built in 1958 and added-onto in 1972 can have cloth-braid ungrounded NM in the original rooms and plastic-jacketed NM with a ground in the addition. ACS year-built will report 1958.

Armored cable — BX, Type AC is the other cloth-era method people photograph and misname. Sprague Electric listed flexible steel-armored conductors in 1899. The production version was “BX”; the name stuck as a GE trade name. AC first appeared in the 1903 NEC and, Dini says, became popular around 1930, the same period knob-and-tube was waning. The armor can serve as an equipment grounding path; AC made after 1959 requires an aluminum bonding strip under the armor to improve that path. Older AC without the bonding strip is a different grounding conversation from cloth NM with no ground at all. The Fire Protection Research Foundation’s 2008 aging study found older armored cable without the bonding strip with armor resistances that in some cases were more than double the original design value. That is a grounding-path finding, not a “cloth is cloth” finding.

The insulation on the conductors, in both methods, was gum-rubber for a long time — a sulfur-cured compound that required the copper to be tinned because the sulfur attacked bare copper. Dini: during the 1950s the industry began transitioning residential wire insulation from rubber to thermoplastics; PVC does not suffer from the brittleness and cracking with age that was typical of the older rubber. The FPRF aging project, harvesting wiring from 30 houses, made the same split: thermoset rubber from before the 1950s was still performing in many residential environments, but older rubber compounds become brittle and are a potential hazard when subjected to bending, abrasion, or harsh usage; thermoplastic insulated wires typical of the 1950s and later continued to perform with excellent results under most conditions. Condition of the rubber, not the word “cloth” on a 4-point form, is the finding.

Then the 1962 line. Dini, from the NEC: in 1962 the Code was revised to require all branch circuits to include a grounding conductor or ground path to which the grounding contacts of the receptacle must be connected. That effectively discontinued non-grounding-type receptacles except for replacement use in existing installations where a grounding means might not exist. Earlier versions of NM-with-ground permitted an undersized grounding conductor (No. 16 AWG ground on 14 and 12 copper NM); 1969 ended that for 14, 12 and 10 gauge NM. So “early grounded cloth” is a real product: cloth-jacket or early plastic NM that does contain a ground, sometimes an undersized one. Treating every cloth jacket as ungrounded is how people miss a ground that is already there — and treating every cloth jacket as fine because “it has a ground” is how people miss brittle rubber on the current-carrying conductors.

Cloth: the job is usually smaller than a whole-house rewire, and sometimes it is not

When the work is a circuit, a room, or a GFCI

A few damaged runs in an attic, rodent chewing on a cloth jacket, or a kitchen that is already being opened are circuit-scale jobs. The model code’s replacement rule for ungrounded receptacles — 406.4(D)(2) in recent editions — permits a non-grounding receptacle to be replaced with another non-grounding receptacle, with a GFCI receptacle marked “No Equipment Ground,” or with a grounding-type receptacle that is GFCI-protected and marked “GFCI Protected” and “No Equipment Ground.” That is shock protection. It is not an equipment grounding conductor, and it is not a rewire. Surge protective devices that need a ground still do not have one.

Where Type AC armor is continuous and tests as a grounding path, a grounding-type receptacle on that circuit can be a different, legitimate landing. That determination is a licensed electrician’s, with a tester, not a homeowner’s with a three-prong wish.

When the work is the house

Whole-house cloth replacement is the job when the rubber is failing in multiple rooms, when the insurer or the 4-point inspector will not accept the system in its current condition, when the house is being opened for a remodel anyway, or when ungrounded circuits are being asked to carry a modern load they were not designed for. It is also the job when someone has been adding three-prong receptacles without GFCI protection and without a ground — a cosmetic lie that a buyer’s inspector will not miss.

A new panel does not remediate brittle rubber in the walls. A service upgrade does not add a grounding conductor to 1952 NM. Those are panel conversations that often travel with this one. They are not substitutes for it.

The cloth insurance conversation is about condition — and it is not knob-and-tube

Citizens’ 1 March 2023 Home Condition Requirements sheet names knob-and-tube and aluminum branch wiring as unacceptable conditions. It does not name cloth-jacket rubber-insulated cable as a third uninsurable category on that sheet. Fuses are listed as acceptable. Hazardous conditions — inadequate fusing, frayed or loose wiring, double taps — are listed as unacceptable. A 4-point inspection that reports damaged cloth insulation, overfusing, or other hazardous findings is a different paper from a 4-point that reports intact cloth NM with no hazardous conditions.

That is not a prediction that every carrier will write a cloth-wired house. It is a description of one dated, named sheet. Other Florida carriers, and carriers in the other four states in our store, may treat cloth as a decline, as a surcharge, or as a documentation problem. We did not find a second named, dated, public underwriting FAQ of Citizens-level specificity that defines cloth the way Answer ID 1550 defines aluminum, and we will not fill that gap from broker blogs. Ask the carrier that will bind the policy what the 4-point must show.

HyreElectrical analysis: the practical error is using “cloth” as a synonym for knob-and-tube in an insurance email. Knob-and-tube is a named unacceptable condition at Citizens. Cloth is a description of a jacket. An inspector who writes “cloth/K&T” as one checkbox is collapsing the three-era table on this page. Ask for the method to be named.

Aluminum branch wiring is a connection problem — and a full copper rewire is only one of three CPSC methods

Aluminum branch wiring has its own child page, and this parent will not duplicate it. The depth on CPSC Publication 516, on COPALUM versus AlumiConn versus copper replacement, and on what Citizens will accept as documentation, lives at aluminum branch wiring remediation. What belongs here is the parent-level distinction: aluminum is the era in which a recognized repair is not replacement.

CPSC Publication 516 (June 2011, still the current numbered pamphlet as of our 5 September 2026 retrieval) names three methods it will treat as a permanent repair of residential aluminum branch-circuit wiring: complete replacement with copper cable; COPALUM crimp pigtailing at every connection; and AlumiConn set-screw pigtailing, which staff call the next-best alternative if COPALUM is not available locally. Twist-on connectors and CO/ALR devices are not, in CPSC’s published view, a permanent repair. COPALUM and AlumiConn leave the original aluminum in the walls. Only a copper rewire removes it.

That is why a sales pitch that jumps from “the house has aluminum” to “you have to rewire” is skipping CPSC’s own ranking. It may still be the right job — walls already open, a carrier that will not accept connectors, a remodel that was going to happen anyway. It is not the only CPSC-recognized job. Citizens, again, will accept documented COPALUM or documented AlumiConn as alternatives to a full copper rewire. Other carriers may not. The order of operations that avoids paying twice is on the child page: insurer and lender in writing, then the electrician quotes that named method.

CPSC’s identification advice is the homeowner action: read the markings on the cable jacket in unfinished basements, attics or garages. Aluminum conductors are marked “Al” or “Aluminum” every few feet. “CU-clad” or “Copper-clad” is a different product and is excluded from those repair recommendations. Do not open the panel to check. Year built (roughly 1965 to the mid-1970s) is a reason to look, not proof. The ACS 1960–1979 band on this page is a year-built proxy, and it is an order of magnitude larger than CPSC’s two-million estimate of homes built with the product. The child page does that arithmetic with the 2019–2023 5-year vintage; the bands here use the 2024 1-year vintage. Both are proxies. Neither is remaining aluminum.

A new panel does not remediate aluminum connections in the rooms. A Federal Pacific or Zinsco load center is a different era-hazard and can coexist with aluminum branch wiring; that identification lives on replacing a Federal Pacific panel.

Partial rewire versus whole-house — the answer changes with the era

If this is truePartial work that can be the right jobWhen “the whole house” is the honest scope
Live knob-and-tube, and the carrier will not bind on active K&TRarely. A kitchen-only rewire that leaves live K&T in the bedrooms still leaves live K&T in the house. Citizens’ sheet does not offer a room-by-room exception.Replace every live K&T circuit. Abandoned dead K&T may stay in the walls. Document that it is dead. Ask the carrier what the packet must contain.
Knob-and-tube in one unfinished attic run, the rest of the house already on NM, no insulation on the remaining K&T, carrier will write itReplace the remaining live K&T circuit. Confirm with the carrier in writing that residual dead porcelain is acceptable.If the 4-point cannot distinguish live from abandoned, or if the carrier wants a clean letter that no K&T remains in service, the remaining live circuits are the whole job even if they are few.
Cloth NM, rubber damaged in specific locations, rest intact, circuits that need a ground can take GFCI protection under 406.4(D)(2)Replace the damaged runs. GFCI-protect ungrounded receptacles where the adopted code permits that replacement, labeled correctly. This is not an equipment ground.When damage is widespread, when the carrier or inspector will not accept the system, or when the house is already open for a remodel that will not be cheaper to do twice.
Aluminum branch, walls closed, carrier will accept COPALUM or AlumiConnA CPSC-recognized connector repair at every aluminum connection is a permanent repair of existing aluminum. It is not a rewire. See the child page.Walls already open; carrier or lender requires the aluminum to leave; or the house needs a rewire for other reasons (ungrounded circuits, damaged cable, a service change that is already gutting runs).
The quote is “we’ll replace the outlets” on aluminum, or three-prong receptacles on K&T without GFCI labelsNot the job. CPSC will not call CO/ALR or twist-ons a permanent aluminum repair. Three-prong on ungrounded K&T without GFCI protection and without the required markings is not a grounding upgrade.Refuse that scope. Ask for the method that matches the era.

Partial and whole-house are not cheaper and more expensive versions of one product. They are different answers to different era-questions.

A single-line bid that says “rewire” without naming the method, the circuits, what is abandoned, who patches the walls, and what will be handed to the insurer is not a scope. The FTC’s contractor-hiring advice is the same fact in plainer language: get itemised estimates in writing.

A panel upgrade is a different job. So is adding a charger.

The load center is the bus, the breakers, the enclosure, and often the service rating. The branch wiring is the cables in the walls. Replacing one does not remediate the other. A 200-amp panel on knob-and-tube is a new lid on an old method. An aluminum-wired house with a new Square D load center still has aluminum at the receptacles. The decision rule for the panel — calculated load, hazard-era product, damage, or a utility service change — lives on the panel-upgrade page. Cost numbers for that job live on panel-upgrade cost. This page will not import them and will not invent a combined “rewire plus panel” national figure.

Spaces and amps fail independently there, too. A 200-amp panel can be full; a 100-amp panel can have empty slots and still fail a load calculation. Count spaces on the panel space checker. Run a neighborhood load check on the electrical load calculator, which is labeled as not a stamped calculation. If the reason you are in the walls is a heat pump and a charger, the load conversation and the wiring-era conversation have to happen in the same week, not as two surprises.

Federal Pacific Stab-Lok and Zinsco / Sylvania-Zinsco are named panel products with a published record. They are not a synonym for old wiring. Identification is its own page. A house can have a Stab-Lok and cloth NM, or a later panel and aluminum branch, or a Stab-Lok and knob-and-tube. Three findings, possibly three invoices.

What actually changes the price — and why this page will not ship a national average

Contractor blogs publish round numbers for “rewire a house.” Those round numbers are not a dataset. They do not say which era, whether the walls are open, whether the plaster is historic, whether the attic is finished, whether the panel is in the scope, whether the utility is involved, which edition of the code the city has adopted, or who patches the drywall. Labour rates in Miami-Dade and labour rates in Salt Lake City are not one market. We do not have a sourced, dated survey of completed whole-house rewire invoices, and we will not borrow a blog range to fill the hole. Type the bid. Compare bids only when they share a scope.

What moves a real bid, in terms an electrician can put on a page:

The era, because the method is the labour. Pulling new NM through an unfinished basement and abandoning dead K&T is a different number of hours from fishing every run in a plaster-and-lath two-story with a finished attic. COPALUM at every device, if that is the aluminum job, is a connection-count job, not a pull-count job. Treating those as one “per square foot” is how a cheap bid and an honest bid cannot be compared.

Access. Unfinished basement and accessible attic versus plaster ceilings, lath, brick, and no chase. Occupied house versus vacant. Who repairs the finish — the electrician, a drywall contractor, you — has to be in the scope, or it will show up as a second invoice the week the inspector passes the electrical.

How much of the house is live on the old method. A 1910 house that was already rewired except for two attic circuits is not a whole-house rewire. A 1968 house with aluminum in every wall is. ACS year-built will not tell the electrician which one you are. Opening unfinished space will.

Whether the panel, the service, or both are in the same mobilization. If the calculated load also fails, or the load center is a hazard-era product, doing the wall work and leaving the Stab-Lok is leaving a named problem in place. Combining the jobs can be cheaper than two mobilizations. It can also be two permits and a utility appointment. See the panel-upgrade page for the second bill the utility sometimes sends. This page will not invent a combined price.

Permit and inspection. Named local examples are below. They are a line on the invoice, not the invoice.

Documentation the insurer or lender has asked for. A letter that no knob-and-tube remains in service, photographs of abandoned ends, a named COPALUM or AlumiConn packet, a passing inspection. An invoice that says “pigtail outlets” without naming the method is how a 4-point fails six months later. That paperwork is labour. It should be in the scope.

If a bid is a single number with the word “rewire” on it, it is not yet a bid you can compare. The FTC’s guidance on hiring a contractor is to get itemised estimates in writing; allowances are placeholders. The same rule applies here.

Process, permit and inspection

Identify the era, write a scope that names the method, pull a permit, inspect. The insurer’s paperwork is a parallel track, not a substitute for the building department.

  1. 01
    Identify the method in unfinished space — without opening a live panel

    Porcelain knobs and tubes in an attic or basement; cloth-braid or armored jacket; “Al” or “Aluminum” on an NM sheath. Year built is the prompt. The jacket or the porcelain is the evidence. Do not open the panel to check. A licensed electrician determines what is live, what is abandoned, and what has been spliced.

  2. 02
    Ask the insurer, in writing, before you choose a method

    For knob-and-tube: will you bind on active K&T, and if not, what documentation that it has been removed from service do you need? For cloth: what does the 4-point have to show? For aluminum: which of the three CPSC methods will you accept? Reversing this order is how a household buys the wrong repair.

  3. 03
    A written scope that names the era and the method

    Which circuits. What is pulled, what is abandoned. Who patches walls. Whether the panel is in the job. What will be handed to the insurer. Three quotes that do not share that scope cannot be compared on price.

  4. 04
    Permit, pulled by the electrician

    Rewiring branch circuits is permitted work in the jurisdictions this page sampled. Like-for-like replacement of a 15- or 20-amp, 120-volt switch or receptacle is often exempt; a rewire is not a device swap. Vagueness about who pulls the permit is a warning sign. Miami-Dade and Salt Lake City are named below because we opened their fee sheets, not because they are typical of the United States.

  5. 05
    Work, inspection, documentation

    The inspector is a second qualified person looking at the work. The insurer is a third audience and wants a named method, not a vibe. Rework is a second visit. HyreElectrical will not be any of those people.

Permit fees are local. Here are two that we opened.

JurisdictionPublished lineAmountRetrieved
Miami-Dade County, FloridaMinimum fee for electrical permits$227.905 September 2026
Miami-Dade CountyG080 — residential wiring: new construction, additions, alterations and repairs0.11 per square foot of floor area5 September 2026
Miami-Dade CountyG005 — general wiring outlet box$2.59 per outlet5 September 2026
Miami-Dade CountyG045 — panel board, switchboard, control panel$32.21 per board5 September 2026
Miami-Dade CountyLike-for-like replacement of 15–20 A, 120 V wall switches and receptaclesExempt from permit (device swap, not a rewire)5 September 2026
Salt Lake City, UtahResidential electrical permit, base fee (SLC Code 18.36.100)$595 September 2026
Salt Lake CityService change or alteration (18.36.100)$405 September 2026

Miami-Dade Department of Regulatory and Economic Resources, Electrical Fee Sheet, form 123_01-5 dated 7/26. Miami-Dade permit-exemption list for electrical device swaps. Salt Lake City Consolidated Fee Schedule, amended 16 June 2026 by Ordinance 2026-29. These are published lines, not quotes for your house.

HyreElectrical analysis: on a 2,000-square-foot house, Miami-Dade’s G080 line at $0.11 per square foot is $220 — below the $227.90 minimum — so the minimum governs unless other category lines (outlet boxes, a panel board) push the total over. Salt Lake City’s published residential base fee is $59; a whole-house rewire is not the $40 service-change line, and the electrician who pulls the permit should name which lines apply. The same job category is constructed differently two states apart. That spread is why this page will not ship a national permit fee. Your building department is the authority.

Weatherization, historic houses, and why “just insulate around it” is a local-code question

An energy retrofit is one of the most common ways live knob-and-tube gets buried. It is also a place where the model code and a handful of state amendments disagree, and where a federal weatherization program has spent forty years telling states to follow the local electrical code rather than a DOE national rule.

In 1987 the NEC (then Section 324-4) was revised to prohibit concealed knob-and-tube in hollow spaces insulated by loose or rolled material; later editions add foamed-in-place. DOE’s Weatherization Assistance Program restated that change in program guidance and, in an 21 October 1988 memorandum that still appears in later archived WPNs, put responsibility on the states to ensure that insulation around knob-and-tube conforms to the applicable codes in the jurisdiction where the work is being performed. Washington, Oregon, and some local jurisdictions have amended the model rule. Washington Administrative Code 296-46B-394, for example, does not prohibit loose or rolled thermal insulation in spaces containing existing knob-and-tube if a licensed electrical contractor surveys the wiring and certifies it is in good condition, the insulation meets Class I specifications with a flame spread of 25 or less, foam is not used, and overcurrent protection complies with the 60°C column of the ampacity table via circuit breakers or Type S fuses.

That is a named state amendment, not permission to blow cellulose over live K&T in Miami-Dade. Florida did not adopt Washington’s exception by virtue of this paragraph. If you are insulating, the sequence is: licensed electrician identifies whether the K&T is live; the adopted electrical code, including any local amendment, says whether insulation may envelop it; then the insulation contractor works. Reversing that sequence is how a weatherization job becomes an electrical fire conversation. CPSC staff said as much in 1980, before the 1987 code change: have the wiring inspected in areas where insulation is to be installed; look first for frequent fuse-blowing, flickering lights, or hot outlet covers.

Historic fabric is the other constraint the square-foot blogs skip. Fishing NM through plaster-and-lath without destroying the finish is slow. Surface raceway, or opening one face of a wall on a room-by-room remodel, are different jobs from a gut. A preservation commission may have a view on visible work; the building department still has a view on concealed work. Neither is a reason to leave damaged live conductors in place. Both are reasons the bid has to describe access.

How to hire, and how to check the license

  • Ask for the number, then check the issuing board

    Not the van door and not a marketplace badge. Florida’s Electrical Contractors’ Licensing Board issues certified EC licenses that are statewide and registered licenses that are local. California’s Contractors State License Board issues C-10 (Electrical). Texas licenses electricians through the Texas Department of Licensing and Regulation — master, journeyman and electrical contractor are different credentials. Utah uses DOPL; Nevada’s State Contractors Board classifies electrical as C-2. Re-check on the date you hire.

  • The class has to cover the job

    A valid license for swapping receptacles is not automatically a license you want on a service change and a whole-house pull. Ask whether they pull permits for rewires and, if the panel is in the job, for service equipment in this jurisdiction.

  • Insurance is a certificate with an expiry date

    General liability, and workers’ compensation where they have employees. An assurance is not a certificate. A rewire that opens walls is a property-damage conversation as well as an electrical one.

  • The estimate names the era and the method in the three-era table

    Knob-and-tube replacement, cloth-circuit replacement, aluminum COPALUM, aluminum AlumiConn, or aluminum copper rewire. What is abandoned. Who patches. Whether the panel is included. What the insurer will be handed. Three quotes that do not share that scope cannot be compared on price.

  • HyreElectrical will not be the contractor

    We do not perform, supervise, inspect or warrant electrical work. Matching is still being built. Submitting an enquiry is not a service call, and no electrician receives your details unless you agree.

Where we actually have records

HyreElectrical is an information site and a matching project. It is not an electrical contractor, and it does not have a service radius. What we do have is a contractor store we counted on 5 September 2026: 16,369 companies across 5 states — Florida 12,114, Utah 1,489, Nevada 1,066, California 903, Texas 839. 74% of those companies are in Florida. The other 45 states are not in this store. Nothing here is a national directory of electricians, and a page that used these counts as one would be misusing them.

If you are in those five states, the useful next step is a licensed electrician who already pulls permits in your jurisdiction, checked against the board that issued the license. If you are not, the same hiring questions apply and our store has nothing extra to add. The enquiry form is how matching, as it is built, will know which records are relevant.

Florida12,114
74% of the store
Utah1,489
Nevada1,066
California903
Texas839

HyreElectrical contractor store, counted 5 September 2026 from company-state records. A research sample in five states, not a census of the trade.

What the fire numbers actually measure — and what they do not

Old wiring is a fire conversation, and it is a conversation in which round numbers get attributed to the wrong product. This page will use the federal and NFPA figures as they are published, with their denominators.

CPSC’s 2019–2021 Residential Fire Loss Estimates (July 2024 staff report, retrieved 5 September 2026) put electrical-distribution equipment at an estimated annual average of 17,300 residential structure fires, 140 deaths, and 640 injuries over those three years. Installed wiring, a subset, averaged 7,600 fires, 50 deaths, and 230 injuries a year. Receptacles and switches averaged 2,300 fires; panel boards 700. Those are equipment-involved estimates from NFIRS and NFPA’s fire-department survey. They are not a count of knob-and-tube fires, cloth-NM fires, or aluminum-connection fires. CPSC does not publish that split.

NFPA Research, in a 1 May 2026 report by Tucker McGree, estimated that in 2020–2024 local fire departments responded to an annual average of 46,652 home electrical structure fires — a broader net that includes fires where electrical failure or malfunction was a factor contributing to ignition, or where electrical distribution, lighting, or power-transfer equipment was involved. Those fires caused an estimated annual average of 527 civilian deaths, 1,580 civilian injuries, and $2.4 billion in direct property damage, and accounted for about 13% of home structure fires and 18% of home structure-fire deaths. That is a different definition from CPSC’s electrical-distribution equipment table. Both can be true. They are not interchangeable.

Age of housing is a risk factor in the federal record, with a sample caveat that copy usually drops. A 10 March 2003 CPSC economics memorandum on AFCIs, citing the 1990 CPSC epidemiological study Residential Electrical Distribution System Fires, states that 85% of all such fires involved housing over 20 years old — and, in the footnote, that the study was based on 149 investigated fires in 16 cities and does not represent a statistically representative sample. CPSC’s 19 May 1993 news release, selecting home electrical-system fires as a 1995 priority, said data showed a disproportionately high frequency of electrical-system fires in homes more than 40 years old, and that about one-third of US homes were then more than 40 years old. Those are CPSC’s sentences. They are not a relative-risk ratio we can compute from ACS year-built, and they are not a claim that knob-and-tube causes a stated share of the 7,600 installed-wiring fires.

The useful conclusion is narrower. Installed wiring is a real, counted slice of residential fire loss. Older housing is over-represented in the electrical-distribution fire investigations CPSC has published, on a sample that CPSC itself flags as not nationally representative. The mechanism for knob-and-tube-plus-insulation is independently stated by CPSC staff (1980) and by the NEC handbook commentary on Article 394.12. The mechanism for aluminum is independently stated in Publication 516. The mechanism for aged rubber is independently stated by UL’s Dini and by the FPRF aging project. None of those mechanisms needs a fabricated “K&T causes 30,000 fires a year” statistic, and we have not found a CPSC or NFPA table that supports one.

Tools and pages that continue this decision

Method and limitations

  • Research question

    When is whole-house rewiring the job, and how does the answer change across knob-and-tube, early cloth-insulated cable, and aluminum branch wiring — including the insurance conversation each era actually produces?

  • Sources

    CPSC Publication 516 and CPSC news releases 80-002 (1980), 93-priority (1993), 96-129 (1996), and the 2003 AFCI economics memorandum; CPSC 2019–2021 Residential Fire Loss Estimates (July 2024); NFPA Research home-electrical-fires report (McGree, 1 May 2026); NFPA 70 as the model code (Articles 394, 320, 334, 406.4(D)); Dini, UL, 2006, history of residential wiring practices; FPRF / UL Residential Electrical System Aging project (2008); Census Bureau ACS 2024 1-year table B25034; Citizens Home Condition Requirements (1 March 2023) and FAQ 1550 (updated 16 April 2026); Miami-Dade Electrical Fee Sheet (form 123_01-5, 7/26) and permit-exemption list; Salt Lake City Consolidated Fee Schedule (amended 16 June 2026); DOE archived WAP guidance on knob-and-tube; Washington WAC 296-46B-394; FTC contractor-hiring guidance. All retrieved 5 September 2026. URLs in the source list.

  • What we calculated

    Combined ACS bands (pre-1960 original-construction proxy; 1940–1959 cloth-era proxy; 1960–1979 aluminum-era proxy) and their shares of the ACS 2024 1-year US total. A 2,000-square-foot illustration of Miami-Dade G080 against the $227.90 minimum. We did not estimate remaining K&T, remaining cloth, or remaining aluminum dwellings.

  • ELE-26 is not this page

    A planned housing-era research asset is not written. Nothing here claims findings from it. ACS year-built is labeled, every time, as a proxy for original construction, not current condition.

  • Limitations

    Citizens is one Florida residual-market carrier. Other carriers, including in Florida, may underwrite these methods differently; we did not find a second named, dated, public FAQ of equivalent specificity for knob-and-tube or cloth, and we will not fill that gap from broker blogs. ACS 2024 1-year estimates have larger margins of error than a 5-year file; the aluminum child page uses the 2019–2023 5-year vintage for its 1960–1979 band. CPSC’s 85% “over 20 years old” figure is from 149 fires in 16 cities and is not a nationally representative sample — CPSC says so in the footnote. There is no public national count of remaining K&T, cloth, or aluminum dwellings. Cost is omitted as a national average because we do not have a sourced invoice survey.

  • Not a stamp, not a quote, not DIY

    Nothing on this page is a diagnosis of your house, a price, legal or insurance advice, or an instruction to open a live panel or splice a conductor. Rewiring is licensed work. HyreElectrical does not perform it.

Questions

Do I need to rewire my whole house?
Only if the wiring method in the walls is the problem, and only to the extent that method and your insurer require. Knob-and-tube, cloth-insulated cable, and aluminum branch wiring are three different findings. A named Florida residual-market carrier lists active knob-and-tube as unacceptable with no repair-in-place path on its published sheet; the same carrier will accept documented COPALUM or AlumiConn as aluminum remediation. Cloth is often a condition-and-grounding conversation, not an automatic whole-house pull. A licensed electrician looking at unfinished space names the method. HyreElectrical does not perform electrical work.
How can I tell if I have knob-and-tube, cloth, or aluminum wiring?
In unfinished attics, basements or garages, without opening the panel. Knob-and-tube is individual conductors on porcelain knobs, passing through porcelain tubes. Cloth NM is a woven fabric jacket, often dark, over rubber-insulated conductors; armored cable (BX) is a spiral metal jacket. Aluminum NM is marked “Al” or “Aluminum” on the plastic sheath every few feet; “CU-clad” is a different product. Year built is a reason to look, not proof. Do not open the panel or outlet boxes to check.
Is knob-and-tube wiring illegal?
Existing knob-and-tube is not banned by a national removal order. NFPA 70, Article 394, still describes the method and permits it for extensions of existing installations or by special permission. New concealed K&T in cavities insulated with loose, rolled or foamed-in-place material that envelops the conductors is a “uses not permitted.” Some cities are stricter; some states amend the insulation rule. Insurance is a separate conversation: Citizens Property Insurance lists knob-and-tube as an unacceptable condition on its 1 March 2023 new-business sheet.
Can I insulate over knob-and-tube wiring?
Not under the model National Electrical Code, which since a 1987 revision has prohibited concealing knob-and-tube in hollow spaces insulated by loose, rolled, or (in later editions) foamed-in-place material that envelops the conductors. Some states amend that rule — Washington’s WAC 296-46B-394 is a named example, with an electrician’s survey, Class I insulation, no foam, and specified overcurrent protection. CPSC staff warned in 1980 that confining the heat of damaged or overfused wiring with thermal insulation increases fire potential. Have a licensed electrician identify whether the K&T is live before anyone blows insulation. Your adopted code, not this paragraph, is the authority.
Will homeowners insurance cover a house with knob-and-tube or cloth wiring?
Only that company can say. Citizens, Florida’s residual market, lists knob-and-tube as an unacceptable condition on its 1 March 2023 Home Condition Requirements sheet and does not give it the remediation footnote it gives aluminum branch wiring. Cloth-jacket cable is not named as a separate uninsurable category on that sheet; hazardous conditions still are. Other carriers may decline, surcharge, or accept documented condition. Get the answer in writing from the carrier that will bind the policy, before you pay for work.
Is replacing two-prong outlets with three-prong outlets the same as rewiring?
No. The model code (406.4(D)(2) in recent NEC editions) allows a non-grounding receptacle to be replaced with a GFCI receptacle marked “No Equipment Ground,” or with a grounding-type receptacle that is GFCI-protected and so marked. That is shock protection. It does not install an equipment grounding conductor, and it does not replace knob-and-tube, cloth NM, or aluminum. Installing three-prong receptacles on ungrounded wiring without GFCI protection and without the required markings is not an upgrade.
Does a panel upgrade fix old wiring in the walls?
No. A panel upgrade changes the load center — the bus, the breakers, often the enclosure, sometimes the service rating. It does not put a grounding conductor in 1930s knob-and-tube, restore brittle rubber on 1950s NM, or remediate aluminum connections at receptacles. Those are this page’s job. Hazard-era panels (Federal Pacific Stab-Lok, Zinsco) are a different finding and can coexist with any of the three wiring eras.
How much does it cost to rewire a house?
Whatever the written bid says for your era, your access, your circuit count, your finishes, your permit, and whether the panel is in the job. This page does not publish a national average, because those variables move the invoice too far for a roundup to help, and we do not have a sourced survey of completed rewire invoices. Compare bids only when they name the same method. Permit fees in two jurisdictions we opened: Miami-Dade’s electrical minimum is $227.90; Salt Lake City’s residential electrical base fee is $59. Neither is your price.
Can I rewire my own house?
No. Branch-circuit rewiring is licensed work. This page will not walk you through pulling cable, splicing onto knob-and-tube, or crimping aluminum. Opening a live panel or a live K&T splice is how people are injured. If you smell burning, see sparks, or feel heat at a cover, stop using the affected circuits and call a licensed electrician. HyreElectrical does not perform electrical work and matching is not an emergency dispatch line.
Does HyreElectrical rewire houses?
No. HyreElectrical is an independent information site. We do not perform, supervise, inspect or warrant electrical work. We hold verified contractor records in Florida, Utah, Nevada, California and Texas — 16,369 companies as of 5 September 2026, 74% of them in Florida — and matching is still being built. An enquiry is not a booking, and no electrician receives your details unless you agree. See how we source and correct what we publish.

Written and audited by

HyreElectrical Research Desk

Primary-source research and fact checking

We read the model code, the federal safety notice, the municipal fee sheet or the utility tariff ourselves, and we publish the figure with the document it came from and the date we retrieved it. Where a number cannot be traced to a primary source, we publish the shorter page and say what we could not verify. HyreElectrical does not perform, supervise or warrant electrical work. Authorship is organisational: this desk, not a named persona.

10
long-form launch pages in this layout
5
states with verified licence records
16,369
electrical companies in those records
74%
of the store is Florida — disclosed first, not footnoted

How this desk works

  • Primary sources only. Code statements come from NFPA 70 as the model code. Safety statements come from CPSC. Permit fees come from the city or county fee sheet. Utility charges come from the filed tariff. We do not cite a blog that cites a source; we open the source.
  • Our contractor store is five states, and 74% of it is Florida. Any figure built on that store is titled to those states and names the concentration in the first screen. It is not a national sample of electricians.
  • Load calculations on this site are a published simplification in the shape of NEC 220.82 — first 10 kVA at 100%, remainder at 40%, HVAC at 100%, EVSE at 125%. They are labelled as not a stamped calculation. A licensed electrician using the adopted edition does that work.
  • No national price for a panel upgrade is shipped. Labour rates, the adopted code edition, whether the utility is involved, and the state of the existing wiring move the invoice too far for a roundup to help. Cost intent lives on the cost page; this page explains the decision.
  • We do not perform electrical work, and we take no payment for placement, ranking or a favourable mention. Nobody buys a position on this site.

Data as of 5 September 2026. Authorship on this site is organisational: the analysis belongs to the desk rather than to a named individual, and we do not publish credentials we do not hold. Our editorial policy sets out how we source, date and correct what we publish.

Sources & retrieval dates

  1. NFPA 70, National Electrical Code — standard development , Cited as the model code. Article 394 (concealed knob-and-tube): uses permitted limited to extensions of existing installations or special permission; uses not permitted include insulated hollow spaces that envelop the conductors. Article 320 (Type AC). Article 334 (NM). 406.4(D)(2) replacement of non-grounding receptacles. Confirm the edition your jurisdiction adopted. Retrieved 2026-09-05.
  2. David A. Dini, P.E., Underwriters Laboratories — Some History of Residential Wiring Practices in the U.S. (2006) , Knob-and-tube construction and 1930s phase-out; AC/BX listing 1899 and 1903 NEC; NM listed 1926 (Rome Wire / Romex); cotton braid to thermoplastic; 1947/1956/1962 grounding-receptacle and branch-circuit grounding dates; rubber versus PVC conductor insulation; AC bonding strip after 1959. Retrieved 2026-09-05.
  3. CPSC — Repairing Aluminum Wiring, Publication 516 , June 2011. Three permanent methods for aluminum branch-circuit wiring; identification from jacket markings; do-not-open-the-panel advice. Depth on this source is on the aluminum child page. Retrieved 2026-09-05.
  4. CPSC news release 80-002 — Check electrical wiring before installing thermal insulation , 6 February 1980. Staff estimate of more than 2,000 household fires a year when thermal insulation is ignited by faulty wiring or lighting fixtures (~3% of then-estimated 75,000 electrical-system fires). Mechanism: heat confined by thermal insulation. Retrieved 2026-09-05.
  5. CPSC news release — Home electrical system fires selected as 1995 priority , 19 May 1993. Disproportionately high frequency of electrical-system fires in homes more than 40 years old; about one-third of US homes then more than 40 years old. 1990 estimate: 42,000 fires involving home electrical wiring. Retrieved 2026-09-05.
  6. CPSC news release 96-129 — Program to prevent home electrical wiring system fires , 22 May 1996. More than 40,000 fires a year from problems with home electrical wiring; nearly 350 lives a year over the prior decade from electrical-equipment fire deaths. Wiring components wear out; older systems struggle with modern loads. Retrieved 2026-09-05.
  7. CPSC — 2019–2021 Residential Fire Loss Estimates (David Miller, July 2024) , Table 4a–4c. Electrical-distribution equipment: 17,300 fires, 140 deaths, 640 injuries annual average. Installed wiring: 7,600 fires, 50 deaths, 230 injuries. Unintentional residential structure fires; NFIRS and NFPA survey. Not a wiring-method split. Retrieved 2026-09-05.
  8. CPSC economics memorandum — AFCI replacements (10 March 2003) , Cites the 1990 CPSC study Residential Electrical Distribution System Fires: 85% of such fires involved housing over 20 years old, based on 149 investigated fires in 16 cities, not a statistically representative sample. Footnote in the memorandum itself. Retrieved 2026-09-05.
  9. NFPA Research — Home fires caused by electrical failure or malfunction (Tucker McGree, 1 May 2026) , 2020–2024 annual average 46,652 home electrical structure fires; 527 civilian deaths; 1,580 civilian injuries; $2.4 billion direct property damage. About 13% of home structure fires and 18% of home structure-fire deaths. Broader definition than CPSC’s electrical-distribution equipment table. Retrieved 2026-09-05.
  10. U.S. Census Bureau — ACS 2024 1-year, table B25034, Year Structure Built , United States housing units by year built. Used only as a year-built proxy for original construction method, never as a count of remaining K&T, cloth, or aluminum-wired homes. HyreElectrical combined pre-1960, 1940–1959 and 1960–1979 bands and computed shares of the table total. Retrieved 2026-09-05.
  11. Citizens Property Insurance — Home Condition Requirements (HO-3, HO-8, DP-1, DP-3) , Dated 03.01.23. Knob and tube wiring listed as an unacceptable condition, with no remediation footnote. Aluminum branch circuit wiring listed as unacceptable with a documentation-of-remediation footnote. Fuses listed as acceptable. 4-point required for homes over 20 years old. Retrieved 2026-09-05.
  12. Citizens Property Insurance — FAQ: Is aluminum branch wiring acceptable? , Answer ID 1550. Updated 16 April 2026. Multi-strand acceptable; single-strand not acceptable unless documented copper rewire, COPALUM, or AlumiConn. Cited here only as the aluminum contrast to the K&T line on the condition sheet. Retrieved 2026-09-05.
  13. Miami-Dade County — Electrical Fee Sheet , Form 123_01-5, dated 7/26. Minimum electrical-permit fee $227.90. G080 residential wiring 0.11 per sq ft. G005 outlet box $2.59. G045 panel board $32.21. Retrieved 2026-09-05.
  14. Miami-Dade County — electrical permit exemptions , Like-for-like replacement of 15–20 A, 120 V wall switches and receptacles is exempt. Electrical work otherwise requires a permit. A rewire is not a device swap. Retrieved 2026-09-05.
  15. Salt Lake City — Consolidated Fee Schedule , Amended 16 June 2026 by Ordinance 2026-29. Residential electrical permits: base fee $59; service change or alteration $40 (SLC Code 18.36.100). Retrieved 2026-09-05.
  16. U.S. Department of Energy — archived WAP guidance on knob-and-tube (WPN 02-5 archive) , Restates the 1987 NEC change (then 324-4) prohibiting concealed K&T in insulated hollow spaces, and the 21 October 1988 policy that states must ensure insulation around K&T conforms to applicable local codes. Notes Washington, Oregon and some Ohio jurisdictions have amended the model rule. Retrieved 2026-09-05.
  17. Washington Administrative Code 296-46B-394 — Concealed knob-and-tube wiring , Named state amendment: loose or rolled thermal insulation in spaces containing existing K&T permitted only with a licensed contractor’s written survey, Class I insulation (flame spread 25 or less), no foam, and overcurrent protection per the 60°C column via breakers or Type S fuses. Not a national rule. Retrieved 2026-09-05.
  18. Fire Protection Research Foundation / UL — Residential Electrical System Aging Research Project (2008) , Thirty harvested houses. Pre-1950s rubber insulation can become brittle with bending and abrasion; thermoplastic from the 1950s onward performed well in testing. Older AC without bonding strip showed elevated armor resistance. Overfusing of 14/12 AWG with 30 A plug fuses observed. Most hazardous conditions attributed to code non-compliance rather than inherent aging alone. Retrieved 2026-09-05.
  19. Florida Electrical Contractors’ Licensing Board , Certified electrical contractor (EC) licenses are statewide; registered licenses are limited to the local jurisdictions that issued a competency card. The board is the issuing authority in Florida, which holds 74% of this site’s contractor records. Retrieved 2026-09-05.
  20. Federal Trade Commission — hiring a contractor , Get itemised estimates in writing. Allowances are placeholders. This page treats a single-line “rewire” number as an incomplete scope for the same reason. Retrieved 2026-09-05.
  21. HyreElectrical contractor store , 16,369 electrical companies in 5 verified states (FL 12,114, UT 1,489, NV 1,066, CA 903, TX 839), counted from company-state records on 5 September 2026. 74% Florida. A research sample, not a national census and not a recommendation of any firm. Retrieved 2026-09-05.

The era, then a licensed electrician

Name the method in unfinished space, ask the insurer which remediation it will accept, then find a licensed electrician who already pulls permits in your jurisdiction. HyreElectrical does not do the work.

Find a local electrician Aluminum branch wiring

HyreElectrical does not perform, supervise, inspect or warrant electrical work. This page is general information, not a diagnosis, not a quote, not legal or insurance advice, and not an instruction to open a live panel or splice a conductor. Matching is still being built; an enquiry is not a service call. Permit fees are those of the named jurisdictions on the retrieval dates above and are not your price. ACS year-built figures are a proxy for original construction method, not a census of remaining wiring.